To avoid moist inside air from contacting chilly surfaces near the ridge, You'll need a genuine air barrier and a real insulation layer. The proper way to repair this issue is to show the rafter bays -- both from higher than or below, It really is your choice -- and pull out the fiberglass insulation. Set the fiberglass in a dumpster. Then fill the rafter bays with spray polyurethane foam.

If you put in 2x4s (or 2x3s on edge, put in with prolonged screws) perpendicular into the rafters, you might address a lot of the thermal bridging concern without the really need to add a layer of rigid foam.

This article will focus on insulated sloped roofs. The approaches explained listed here can be used to construct an insulated cathedral ceiling in excess of an awesome home, a section of sloped roof earlier mentioned a kneewall, or any very similar area of insulated sloped roof.

Q. "I are actually working with rigid breadboard style expanded polystyrene during the rim joists and imagined exactly the same may be place underneath the sheathing between the rafter bays."

I now recognize that stucco can not be placed on a roof, so I will revert for the a metal roof, but nonetheless want to have an unvented attic. I've read by "Creating a conditioned attic", and am continue to undecided concerning The simplest way to move forward.

2. Set up durable web-site-built ventilation baffles in each rafter bay before you spray the foam. Like that you end up with a vented cathedral ceiling.

I am a homeowner with cathedral ceilings which were extra in the course of reworking and enlargement of my dwelling while in the late 90s. Just the ridge beam is exposed. The remainder of the ceiling is covered with drywall. With the decades There was some condensation leak down the side of your ridge beam on some mornings in March/April.The home is about four miles through the coast in Southern Califonia, so zone 3b. You can find 4 recessed lights from the ceiling over the side of the beam that will get the condensation, but In addition there are lights within the side that is often More about the author dry. There isn't a air-con in the house. Heat is employed through the evening only about a dozen nights a year, not during the condensation. Commonly the Home windows are open up. It seems the condensation exhibits up on mornings when there isn't a maritime layer (no clouds each morning) along with the temperature heats up reasonably early following a extremely awesome night time. The problem ceiling faces east/west as well as condensation is to the east struggling with side of your beam. The roof is black asphalt shingle. I'm sure that there's no caulk/sealant amongst the facet from the beam as well as put where by the drywall butts against it, so There's a modest air hole there.

In the term, no — the code explicitly click for source forbids this technique. Cellulose can only be Employed in an unvented roof assembly when there is an sufficient layer of rigid foam above the roof sheathing or an ample layer of closed-mobile spray foam under the roof sheathing. Cellulose alone received’t work.

As the head of our community HBA, I've strenuously pointed out that foam in excess of a vented flat roof assembly won't give the insulation values promised. Some builders have recommended they could merely seal and stucco in excess of the stucco vents and eradicate the air flow.

A. If your target is to put in a fantastic air barrier, then drywall is definitely ample, providing you seal all penetrations to prevent air leakage. For more on setting up drywall in an airtight method, see Airtight Drywall.

You do not clarify no matter if This can be new construction or perhaps the renovation of an existing building. I alternatively suspect This is a renovation -- or else 1 may well believe that the designer from the creating would also have supplied a design for your roof.

As outlined by section R806.three of your 2006 Worldwide Residential Code (IRC), “At least a one-inch space shall be furnished in between visit the site the insulation as well as roof sheathing and at the location from the vent.” This kind of vent space could be developed by putting in 1 inch by 1 inch “sticks” inside the upper corners of every rafter bay, followed by stiff cardboard, thin plywood, OSB, fiberboard sheathing, or panels of rigid foam insulation.

It looks like you've got an current roof with tile roofing. I'm guessing that you are writing from Europe. It looks like the insulation consists of "tight-fitting Wooden fibre board" in between your rafters -- thickness and R-benefit are not specified.

A. Either technique will get the job done, so long as you get at least the minimal code R-value for your personal roof, and so long as you use building procedures that listen to airtightness.